The most important thing is not to onboard fires. If the unfortunate happens, they must know the fire extinguishing efficiency. For this, need good management and maintenance of fire systems aboard.
25-07-2019 11:14:41 PM - 541

Based on the diagram of firefighting, "Fire control plan", the person in charge of fire fighting equipment have established track records maintenance firefighting equipment periodically. Depending on the size and route of each ship equipped with appropriate fire-fighting system. However, the service equipment on board the firefighting often is:

 

I. EQUIPMENT FIRE ONBOARD
1. Equipment fire detection and warning, including: 

- Fixed fire detectors
- Fire alarm stations
- General Fire Alarm 
- Local fire alarm) 
- Flamable-gas detector)
2. Fire fighting system with the dragon fire, including: 

- Fire mains) 
- The fire pump 
- Emergency fire pump
- The fire hydrants
- The fire hoses
- The fire nozzles
- Internal shore connection
3. Portable fire extinguishers, including:
 
- The fire extinguisher foam (foam) 
- The fire extinguishers, gas (CO2) 
- The extinguisher chemicals (chemical) 
- The fire extinguisher powder (powder) 
- The fire extinguishers Other reserve ( spare-charges)

 

4. Fixed fire extinguishing system engine room, cargo hold are: 


- CO2 fire extinguishing system, 
- gas extinguishing systems (inert gas, helon) 
- Foam fire extinguishing systems (foam) 
- System extinguishing spray (spinkler)

5. Oil shutoff systems, wind, ventilation and emergency exits, including:

- Ventilation system
- Venting pipes
- Dampers
- Emergency shut down
- Fire doors & controls
- Escape routes

6. Emergency escape breathing devices

 
7. FIRE STATION or FIREMAN OUTFITS, including:
- Ffire jacket, pants, gloves, cap, boots
- Breathing apparatus
- Fire axe
- Fireman lifeline
- Safety light

II. INSPECTION AND MAINTENANCE EQUIPMENT FIRE ONBOARD

1. General Regulations on inspection 
of fire fighting equipment should be checked and maintain reliability. Maintenance work must be carried out periodically (weekly, monthly, quarterly and annual). The purpose of the maintenance is to ensure the firefighting equipment is always ready to work state. Calendar maintain and check the following:
 
(1) Check weekly 
- Try operational information systems and internal communication (public address system) 
- Try activities Alarm System General (general alarm) 
- Check breathing (breathing apparatus cylinders) and compressed air leaks 
- Check the status of the outside, the installation location prescribed equipment 

(2) Check the monthly
- Check the number, location of installation, store and general condition of the equipment of firefighting under the layout and equipment of firefighting vessel 
- Check the position of the valve of fire extinguishing system fixed, have put in place "closed" or "open" as prescribed. 
- Check the specified index of the clock pressure wind bottle launch fire extinguishing systems, the spacer ... is at regulation. 
- check valve position indicator and clock regulated pressure wind bottle valve control system quickly. 
- Try to operate the pump fire pumps including fire incident, the pressure dragon fire. Check the leakage of piping, valves, taps and dragon fire 
- Try operating the fire alarm general, the fire alarm sector 
- Testing equipment automatically shut the door against fire 

(3) Check the row precious
- Content such as checking monthly 
- Try active sensors Fire alarm 
- Try operate the hand valve closed ventilation system, ventilation, blocked fire ... (dampers) 
- Try operating the valves of firefighting, the valve block (stop valves) 
- Check control wire fire system CO2 
- Check operating system fire warning automatic fire extinguishing system fixed 
- Check active fire fighting systems misting (spinkler system )
 
 
(4) Check the annual 
Work annual inspection conducted by the crew and the company commissioned onshore. The company was commissioned (RO), check the following items and make report to the registry as follows: 

+ Replace new foam to foam, add more pressure gas bottles (if weight reduction of over 10%), or rather the average powder flour if dough is moist. 
+ Check and additional pressure on the spacer (SCBA), the breathing problem (EEDB), bottles of compressed air 
+ function test fire alarm system 
+ test system operation public information 
+ Try alarm General fire action 
+ try alarm fire area 
+ try operating system quick closing valve 
+ try automatic alarm fire fighting system fixed fire
+ Try operating the fire pumps, including fire pumps incident 
+ Testing pressure of dragon fire, nozzles 
+ Testing activity Fire extinguishing systems spray warehouse paint 
+ Quality control equipment loaded air (if available) 
+ Check the instructions, operating instructions and equipment, labels-labels of prescribed fire IMO
 
2. Periodically check the special 

WW special inspection will be conducted by the company mandated (RO). 
After checking satisfies criteria, must issue certificates of 
safe use of the equipment is checked as follows: 

(1) Periodically 2 years 
- Check the volume of CO2 of the average in the fire-fighting system fixed 
- try enclosed pipe system extinguishing gas 

(2) Periodically 3 years 
- check the quality of the foam system fixed fire 
- then be checked annually 

(3) Periodically 5 years 
- try pressure compressed gas cylinders (SCBA) 
- on testing and pressure testing must be clearly stated on each bottle 

(4) Periodically 10 years 
- Check inside the control valve fixed fire-fighting system
- Try checking pressure fire extinguishers, portable 
- On and data on the pressure test is indicated on each bottle 

(5) Periodically 20 years 
- Try pressure cylinders CO2 fire extinguishing system fixed after manufactured 20 years. 
Then, every 10 years to check back once. 
- Date and pressure tests specified on each bottle.
 
 

Other news

Lifeboat Inspection

Lifeboat Inspection

Service maintenance of lifeboats in GOTCO meet IMO regulations 761 (18) and is authorized by 07 leading manufacturers. GOTCO full processes and equipment to maintain the same strong technical team of professional, experienced.
LIFERAFT INSPECTION SERVICE

LIFERAFT INSPECTION SERVICE

Service maintenance of life rafts in GOTCO comply with the provisions of IMO 761 (18) and is authorized by 14 leading manufacturers with the complete process and equipment for maintenance. Strong team of professional technicians, experienced has been trained and certified by each manufacturer.
Load test for Cranes/ Davits

Load test for Cranes/ Davits

We carry out work related to load testing as follows: - Load test for cranes / pipes - Load test for davits of lifeboat and liferaft
Fire Fighting Equipment Inspection

Fire Fighting Equipment Inspection

According to Chapter II-2, Regulation 10, SOLAS, on board must be equipped with fire-fighting equipment, fire fighting system and throat Pipeline Fire (Fire mains and hydrants) with specific requirements. Thus, maintenance and inspection is also extremely important.
LOAD TEST WATER BAGS - - INNOVATIVE SOLUTIONS AND EFFICIENCY

LOAD TEST WATER BAGS - - INNOVATIVE SOLUTIONS AND EFFICIENCY

Currently, the water bag load test is favored by the test method is simple and safe to download instead crane load test with traditional solids.
ABOUT LIFERAFT

ABOUT LIFERAFT

Life rafts float equipped on most storage media waterway to serve the emergency. To make good use of this life-saving equipment, in addition to inspection and routine maintenance also need to grasp the basic knowledge of it.
IMPORTANCE OF LIFEBOAT INSPECTION

IMPORTANCE OF LIFEBOAT INSPECTION

The lifeboats, rescue boats and launching appliances servicing included: - First time inspection (after new
LIFEBOAT ON SHIPS

LIFEBOAT ON SHIPS

Lifeboats are one of the most important life-saving equipment that are attached to a ship and they can help to save lives of passengers on board a ship in times of emergencies. They can also be kept on shore to rescue people who are in trouble at sea.
LIFERAFT RELEASE SYSTEM & LAUNCHING PROCEDURE

LIFERAFT RELEASE SYSTEM & LAUNCHING PROCEDURE

Life rafts are provided as a life-saving appliance on every seagoing merchant or passenger ship, in addition to the lifeboats. Life rafts are much easier to launch as compared to lifeboats and in case of emergency situations, evacuation from the ship can be done without manually launching any of them as the life rafts are designed with an auto-inflatable system. SOLAS chapter III gives all the details for types and the number of life rafts to be carried as per the size and type of the ship.
Marine services in VietNam

HCM off & workshop

389 (12/1F) Dao Tri St., Dist. 7, HoChiMinh City, Viet Nam 

Phone : 028 - 377 32 140 / 0903 302 314 
Fax : 028 - 377 32 141 
Email : sales@gotco.com.vn 

n

Hai Phong branch & workshop

KM2 + 200 Dinh Vu Street, Dong Hai II, Hai An, Hai Phong City, Viet Nam
Phone : 0225 – 362 9220
Fax : 0225 – 362 9220
Email : sales@gotco.com.vn 

PhuMy branch & workshop

51 Highway –  Tan Hai, Phu My, Ba Ria, Vung Tau City, Viet Nam
Phone : 028 – 377 32 140
Fax : 028 – 377 32 141
Email : sales@gotco.com.vn 

KienGiang branch & workshop

No. 34-35-36, Block A03, Lan Bien Tay Bac New Urban Area, Vinh Thanh Ward, Rach Gia City, Kien Giang Province, Viet Nam

Phone : 028 – 377 32 140

Fax : 028 – 377 32 141
Email : sales@gotco.com.vn

Head office address

Address: 183C / 5P Ton That Thuyet - Ward 4 - District 4 - Ho Chi Minh City. Ho Chi Minh

MST: 031226 5509

Tel: + 84. 28 - 377 32 140

Fax: + 84 .28 - 377 32 141

Email: info@gotco.com.vn

Web: www.gotco.com.vn